Features:
This delicate digital display temperature controller can set Celsius mode or Fahrenheit mode.
The temperature controller has the characteristic of high accuracy
, high sensitivity, high stability.
Wide temperature measurement range from 50 celsius to 110 celsius and supports high temperature protection.
Can be installed directly or embedded in industrial control equipment panel, convenient and quick.
Widely used in the hatching area, equipment case, air conditioning system, temperature control protection and other fields.
Specifications:
Temperature Measurement Range: 50 celsius 110 celsius
Resolution Ratio: 9.9 celsius 99.9 celsius 0.1 celsius , other temperature intervals:1 celsius
Measurement Precision: 0.1 celsius
Control Precision: 0.1 celsius
Return Difference Precision: 0.1 celsius
Refresh Rate: 0.5S
High temperature Protection: 0 110 celsius
Measurement Input: NTC (10K 0. 5percent ) waterproof sensor
Output: 20A Relay
Environmental Requirements:
Temperature Requirement: 10 celsius 60 celsius
Humidity Requirement: 20percent 85percent
Size: 4.8 x 2.8cm 1.89 x 1.10in
Static current: less than 35MA
Pickup current: less than 65MA
Methods of Use:
After
Connecting to the power supply and load (referring to the wiring
diagram), you can supply power for the controller, the color red
manifest for measuring temperature, the following color blue (or red) as
required to set the temperature
In
the case of manifesting real temperature and please press the button
set, the following setting text digital will flash and temperature,
after completing the setting, please wait for 3s it will return
automatically, at this time controller will automatically disconnect
Relay according to the preset temperature, the this senor can meet all
kinds of large power load, please make sure the line is correct
The Description of Light and Digital Tube Status:
Light: The off means Relay is disconnected, and the normal light on shows that the Relay has closed.
Digital
tube: The sign LLL is the open circuit of sensor and the sign HHH means
beyond the measuring range, the controller will forcibly disconnect
Relay, the sign means high temperature protection
The Description of Parameters Function:
Please
press the button SET five seconds and then it can enter to the main
menu of setting, pressing STC(+)and C F ( ) can switch to P0 P8.
About
the adjustment of parameters P0 P8, when you need to adjust P0, firstly
please press STC (+) and C F ( ) at the same time, and the
P0figurewill flash, secondly please press STC (+)and C F ( ) to
adjust, if done, finally please press STC (+) and C F ( ) to confirm
at the same time,P1 P8 which can be set the parameters of each code like
P0according to the needs of their own.
The key C F is a key for switching Fahrenheit or Celsius
Press
the key C F once, and it will manifest F(Fahrenheit mode),and then
press the key C F once, it will show C(Celsius mode), the default mode
is C(Celsius mode),if there is a big temperature error when you use it,
maybe it is F mode.
An example for setting:
If you need to Control the refrigeration equipment
1: Please set into C mode in the code P0:
2:In
the case of manifesting the actual temperature you should press the key
SET, and the following digital of setting text will flash, then press
C F (+) and SET ( ) to set the stop cooling temperature, after setting
please wait for 3 seconds, it will automatically confirm to return.
3:Return
difference setting: Firstly please press the key SET for five seconds
all the time, and it will enter the setting main menu, secondly press
STC (+)and C F ( ) to switch into P1, when switching into P1,please
press STC (+) and C f ( )once at the time, the P0figure will flash,
then please press STC(+)and C f ( )to set to difference value(return
difference means that you should add several degrees to start, for
instance, if the it stops when the stop setting temperature is 25
degrees, you should need to set the cooling temperature to 28 degrees,
the value in the code P1should be set 3 degrees, so the return
difference value is 3 degrees),after finishing that, finally please
press STC(+) C F ( ) at the same time to confirm.
4:The
above steps are set up, the data is automatically saved, and the final
result is, in the control of refrigeration equipment, higher than28
degrees to start the refrigeration, refrigeration to 25degrees to stop.
If you need to control the heating equipment:
1: Please set into H mode in the code P0.
2:In
the case of manifesting the actual temperature you should press the key
SET, and the following digital of setting text will flash, then press
C F (+) and SET ( ) to set the stop heating temperature, after setting
please wait for 3 seconds, it will automatically confirm to return.
3:Return
difference setting: Firstly please press the key SET for five seconds
all the time, and it will enter the setting main menu, secondly press
STC (+) and C F ( ) to switch into P1,when switching into P1, press
STC (+) and C f ( ) once at the time, theP1figure will flash, then
please press STC (+) and C f ( ) to set to difference value(return
difference means that you should add several degrees to start, for
instance, if the it stops when the stop setting temperature is 25
degrees, you should need to set the heating temperature to 22 degrees,
the value in the codeP1should be set 3 degrees, so the return difference
value is 3 degrees),after finishing that, finally please press STC (+)
C F ( ) at the same time to confirm.
4:When
the above steps all are set up,the data are automatically saved ,so as
controlling the heating equipment, it will start heating system less
than 22 degrees, and it will stop heating when the temperature is 25
degrees.
Code
explain
Setting range
Factory setting
P0
Heating cooling
H C
C
P1
Return difference
0.1 30
2.0
P2
Set limit maximum
+ 110
110
P3
Set limits to the minimum
50
50
P4
Temperature correction
15 15
0
P5
Delay start
0 10
0
P6
High temperature alarm
50 110
celsius
OFF
P7
CS FH
CS FH
CS
P8
Factory Reset
ON OF
OFF
Package Includes:
1 x Temperature Controller with probe
.